Quick Start Guide Serial to WiFi Adapter www.wifiandscales.com
Turn the scale off before you plug in the adapter to the serial port. Fasten the adapter with the
screws assure a good connection. If the adapter is plugged in with the power on, the scale can
indicate battery low when the adapter is connected.
For a scale that does not provide adapter power via the d-sub interface an external AC-DC
adapter has to be used. This should be a 9V AC-adapter with minus on the centre pin. The
same type used by the scales.
Start a web browser at a PC connected to the same network as the WiFi Adapter and type in
the address for the WiFi Adapter in the address field.
The webpage for the WiFi Adapter and the Scale comes up shortly.
3.2 The WiFi Adapter scale web GUI
The following commands can be invoked via the web page. By clicking on the buttons
Web page key
Action
UPDATE
This command will update the scale reading. The indicator
will show ERR if the scale is in motion or inaccessible.
TARE
This command is sent to the indicator to tare the scale.
The indicator will not respond if the scale is in motion,
positive overload or negative overload. The indicator will
also not respond if it is displaying a negative gross value.
ZERO
This command is sent to zero the scale. The indicator will
not respond if the scale is in motion, positive overload or
negative overload. The indicator will also not respond if it
is not in gross mode or within the zero range specified in
F4 of the Setup Menu.
AUTO REFRESH ON/OFF
Toggles the automatic refresh of the web page on or off.
GR (if shown)
This command is sent to the indicator to revert to gross
mode. The indicator will not respond if the scale is in
motion, positive overload or negative overload. The
indicator will also not respond if it is not in net mode.
NT (if shown)
This command is sent to the indicator to revert to net. The
indicator will not respond if the scale is in motion, positive
overload or negative overload. The indicator will also not
respond if it is not in gross mode or a tare has yet to be
established.
Configure Alarm Settings
Opens the Alarm configuration page